2002 Chetak And 2003 Legend Evaporative Emission Control System Hookup

0

Filed Under (Bajaj) by admin on 31-10-2010

download
2002 Legend engines have the carburetor air vent hose connected between the 2 way valve and the canister, with a 108 main jet in the carburetor. The 2003 Legend engines have the air vent connected as shown in this diagram and the main jet increased to 120 to compensate for the reduced bowl pressure. All 2003, and subsequent Legend and Chetak engines, will have this hookup as shown with 120 size main jets. Warning: Seemingly small changes can make a big difference in altering the fuel/air ratio. Disconnect hoses or make changes at your peril. There is no horsepower to be gained by disconnecting this passive emission control system

Write a comment