2000 cbr 929 02 sensor replacement wire

You search Auto repair manual PDF 2000 cbr 929 02 sensor replacement wire, if there are search results will appear below. If search results do not exist, please search by others keyword.



  2000 cbr 929 02 sensor replacement wire Direct Download speed 5282 Kb/s

  2000 cbr 929 02 sensor replacement wire Full Version speed 6162 Kb/s



SUZUKI SV 1000 RADIATOR (COOLING SYSTEM) SERVICE MANUAL

0

Filed Under (Suzuki) by admin on 26-02-2011

download
FI SYSTEM MALFUNCTION CODE AND DEFECTIVE CONDITION MALFUNCTION CODE DETECTED ITEM DETECTED FAILURE CONDITION CHECK FOR COO NO FAULT C11 Camshaft position sen- sor The signal does not reach ECM for more than 3 sec . after receiving the starter signal . The camshaft position sensor wiring and mechanical parts (Camshaft position sensor, intake cam pin, wiring/coupler con- nection) C12 Crankshaft position sensor The signal does not reach ECM for more than 2 sec . after receiving the starter signal . The crankshaft position sensor wiring and mechanical parts (Crankshaft position sensor, wiring/coupler connection) C13 Intake air pressure sensor The sensor should produce following voltage . (0.50 V < sensor voltage < 4 .85 V) Without the above range, C13 is indicated. Intake air pressure sensor, wiring/coupler connection C14 Throttle position sen- sor The sensor should produce following voltage . (0.20 V < sensor voltage < 4 .80 V) Without the above range, C14 is indicated. Throttle position sensor, wiring/coupler connection C15 Engine coolant temperature sensor The sensor voltage should be the following. (0.15 V <_ sensor voltage < 4 .5 V) Without the above range, C15 is indicated. Engine coolant temperature sensor, wiring/coupler connection C21 Intake air temperature sensor The sensor voltage should be the following. (0.15 V < sensor voltage < 4 .5 V) Without the above range, C21 is indicated. Intake air temperature sensor, wiring/coupler connection C22 Atmospheric pressure sensor The sensor voltage should be the following. (0.50 V < sensor voltage < 4 .5 V) Without the above range, C22 is indicated. Atm. pressure sensor, wiring/coupler connection C23 Tip over sensor The sensor voltage should be the following for more than 2 sec . after ignition switch turns ON . (0 .20 V < sensor voltage < 4 .80 V) Without the above value, C23 is indicated. Tip over sensor, wiring/coupler connection C24 or C25 Ignition signalCrankshaft position sensor signal is produced and ECM determines the ignition signal but signal from ignition coil is interrupted continuous by 4 times or more. In this case, the code C24 or C25 is indicated. Ignition coil, wiring/coupler connection, power supply from the battery SERVICING INFORMATION 8 .3 C28 Secondary throttle valve actuator No operating voltage is supplied from the ECM, C28 is indicated. STVA can not operate. STVA lead wire/coupler, STVA C29 Secondary throttle valve position sensor The sensor should produce following voltage . (0.10 V < sensor voltage < 4 .90 V) Without the above range, C29 is indicated . Secondary throttle position sensor, wiring/coupler connection C31 Gear position signalGear position signal voltage should be higher than the following for more than 2 seconds. (Gear position switch voltage >_ 0 .6 V) Without the above value, C31 is indicated. Gear position sensor, wiring/coupler connection, gearshift cam, etc. C32 or C33 Fuel injector Crankshaft position sensor signal is produced and ECM determines the injection signal but fuel injection signal is interrupted continuous by 4 times or more. In this case, the code C32 or C33 is indicated. Injector, wiring/coupler connection, power supply to the injector C41 Fuel pump relay No voltage is applied to fuel pump although fuel pump relay is turned ON, or voltage is applied to fuel pump although fuel pump relay is turned OFF . Fuel pump relay, connecting lead, power source to fuel pump relay C42 Ignition switchIgnition switch signal is not input in the ECM . Ignition switch, lead wire/coupler C44 Heated oxygen sensor (HO2S) [For E-02, 19] During 02 feedback control, 02 sensor voltage is higher or lower than the specification . No signal is detected during engine operation or no electrical power is supplied from the battery . HO2S lead wire/coupler connection Battery voltage supply to the HO2S C49 PAIR control solenoid valve (PAIR valve) When no operating voltage is supplied from the ECM, C49 is indicated. PAIR valve can not operate. PAIR valve lead wire/coupler

Incoming search terms:

2001-2002 GL1800 A ABS Speed Sensor Wire Clamp Location INSPECTION/ REPAIR PROCEDURES

0

Filed Under (Honda) by admin on 29-01-2011

download
1. If the VIN is within the preceeding range, inspect the front ABS speed sensor wire clamp according to the following illustrations. 2001-2002 GL1800A ABS Speed Sensor Wire Clamp Location INCORRECT Installation CORRECT Installation Service Bulletin American Honda Motor Co., Inc. 2001-2002 GL1800 ABS Speed Sensor Wire Clamp Location 0112 GL1800 #9*GL1800 #9*0112*2001-2002 GL1800 ABS Speed Sensor Wire Clamp Location*GL1800, ABS Speed Sensor Wire Clamp Location*Motorcycle*1800 2 of 2 ©2001 American Honda Motor Co., Inc. – All Rights Reserved GL1800 #9 DECEMBER 2001 IDENTIFICATION There is no identification mark associated with this Service Bulletin. PARTS INFORMATION There is no parts information associated with this Service Bulletin. WARRANTY INFORMATION The normal warranty claim submission requirements apply. Submit one warranty claim per VIN with the following information only: Inspected and REPAIRED Template: GL#9 Hours: 0.2 hours Parts: None If the clamp is installed correctly on top of the speed sensor, no further action is necessary. 3. If the clamp is installed incorrectly under the speed sensor, remove and reinstall the clamp and speed sensor correctly. Torque the bolts,. Torque: 12 N • m (1.2 kgf • m, 9 lbf • ft) If the speed sensor wire clamp for the front ABS speed sensor is installed incorrectly, the ABS speed sensor air gap may be out of specification. This does not affect ABS speed sensor operation, but the clamp should be installed correctly. Inspect and repair all affected units using the Inspection/Repair procedures listed below. Inspect all unsold units and customer units brought in for service. AFFECTED UNITS 2001-2002 GL1800A units as follows: MODEL 2001 GL1800A All units 2002 GL1800A 1HFSC474*2A100001 – 1HFSC474*2A101643 * = denotes check digit Any unit in the above VIN range may be affected and should be inspected according to the procedures in this Service Bulletin. All units outside of the above VIN range do not require inspection. CUSTOMER NOTIFICATION There is no customer notification associated with this Service Bulletin.

Incoming search terms:

WEGO II Wide-Band Exhaust Gas Oxygen Sensor Interface Installation Instructions

0

Filed Under (Tips and Review) by admin on 27-10-2010

download
1. Turn off the ignition switch before proceeding. 2. Select a convenient mounting location for the Bosch sensor. In general, the sensor should be mounted as close to the exhaust valve or exhaust manifold as practical. When choosing a mounting location, allow several inches clearance for the sensor wire harness. The wire harness must exit straight out from the sensor. Do not loop the harness back onto the sensor body. The sensor responds to oxygen pressure. Excessive backpressure will cause a reading error. For turbocharged applications, you must mount the sensor downstream of the turbo. 3. For temporary use during dyno tuning, you can mount the Bosch wide-band sensor in place of one of the original equipment rear oxygen sensors (after the catalytic converter). You can also use a sniffer in the tailpipe. For permanent mounting, an 18 x 1.5 mm weld nut must be welded onto the exhaust pipe. After welding, run an 18 x 1.5 mm tap through the threads. Failure to clean the threads may result in sensor damage. Note that most automotive muffler shops are familiar with oxygen sensor weld nut installation on custom pipes. Do not install the sensor until after the free air calibration procedure described in the following section. Always use an anti-seize lubricant such as Permatex 133A on the sensor threads. 4. Install the WEGO II unit. The WEGO II unit should be mounted where the LCD display will be visible during testing. You can secure the WEGO II unit with Velcro tape strips. 5. Connect the Bosch sensor to the 6 pin mating connector on the WEGO II wire harness. 6. Refer to Figure 1. Connect the black WEGO II wire to frame ground using the supplied ring terminal. Try to use an existing wire harness ground location. Do not extend the WEGO II ground wire or ground the WEGO II to the battery minus terminal or to the engine. 7. Connect the red WEGO II wire to switched +12 volt power. You can usually find switched +12V power at an accessory fuse on the fuse block. You can use the supplied fuse tap and 3/16″ female crimp terminal for this purpose

WEGO IV Wide-Band Exhaust Gas Oxygen Sensor System Installation Instructions

0

Filed Under (Harley Davidson) by admin on 21-04-2012

download
1. Turn off the ignition switch before proceeding. 2. Select a convenient mounting location for the Bosch sensor. In general, the sensor should be mounted as close to the exhaust valve or exhaust manifold as practical. When choosing a mounting location, allow several inches clearance for the sensor wire harness. The wire harness must exit straight out from the sensor. Do not loop the harness back onto the sensor body. The sensor responds to oxygen pressure. Excessive backpressure will cause a reading error. For turbocharged applications, you must mount the sensor downstream of the turbo. 3. For temporary use during dyno tuning, you can mount the Bosch wide-band sensor in place of one of the original equipment rear oxygen sensors (after the catalytic converter). You can also use a sniffer in the tailpipe. For permanent mounting, an 18 x 1.5 mm weld nut must be welded onto the exhaust pipe. After welding, run an 18 x 1.5 mm tap through the threads. Failure to clean the threads may result in sensor damage. Note that most automotive muffler shops are familiar with oxygen sensor weld nut installation on custom pipes. Do not install the sensor until after the free air calibration procedure described in the following section. Always use an anti-seize lubricant such as Permatex 133A on the sensor threads. 4. Install the WEGO IV unit where the display will be visible during testing. The unit is not sealed and must be mounted in a dry location away from sources of heat. We recommend underdash mounting or use in a dyno lab environment. The unit is not intended for underhood mounting. The unit can be secured by means of Velcro tape strips. Use nylon tie wraps to secure the wire harness near the unit. 5. Working with clamping terminal blocks . All connections to the WEGO IV terminal block must be clearly identified either by means of distinct wire colors (such as shown in Figure 1) or wire labels. If you use different wire colors, mark up Figure 1 for future reference. All connections can be made with 18-20 AWG wire. Wire should be stripped back

Harley-Davidson Softail, Touring, Dyna, Sportster and V-Rod, SELF LEARNING MODULE INSTALLATION MANUAL

0

Filed Under (Harley Davidson) by admin on 17-04-2012

download
STEP 1 – BATTERY CONNECTION Locate the battery and disconnect the negative battery cable. Mount the module in the open area in front of the battery with 2-tie straps or velcro straps, directing the harness from the module towards the 6 o’clock position. STEP 2 – THROTTLE POSITION SENSOR (TPS): Remove the air cleaner assembly and unplug the TPS sensor connector at the TPS sensor. The harness includes (2) TPS connectors which should be routed under the gas tank into the factory wire loom to the TPS sensor. The TPS sensor is located on the left side of the throttle body. Plug the (2) TPS connectors from the module in between the TPS sensor and to the factory TPS connector. STEP 3 – O2 SENSOR: Systems equipped with factory O2 sensors Rear: Unplug the Rear O2 sensor connector from the factory harness, which is located at the Rear exhaust pipe. Route the module’s harness which includes (2) O2 sensor connectors and connect one connector to the Rear O2 sensor and connect the other connector to the main factory O2 sensor connector. Front: Unplug the Front O2 sensor connector from the factory harness, which is located at the Front exhaust pipe. Route the module’s harness which includes (2) O2 sensor connectors, and connect one connector to the Front O2 sensor and connect the other connector to the main factory O2 sensor connector. Systems not equipped with factory O2 sensors NOTE: Many aftermarket exhaust systems are now equipped with plugged O2 sensor bungs which can be removed to accept an aftermarket O2 sensor. Typically these bungs already have a thread size of 18 mm x 1.5 mm. Exhaust systems not equipped with O2 sensor bungs need to have the supplied 18 mm x 1.5 mm thread size bung welded to the exhaust pipe in order to install an O2 sensor. The O2 sensor bung should be installed 3 to 6 inches away from the rear cylinder exhaust port and in front of the exhaust torque tube pipe area. The module prefers to receive information from the O2 sensor from an area that is NOT contaminated from atmospheric air. This air may enter through the tail pipe of an unrestricted or un-baffled exhaust pipe. The bung should not be installed in the “5 to 7 o’clock” area. If mounted in this area the O2 sensor can be damaged. The moisture from the gases exiting from the rear cylinder exhaust port will harm the ceramic shell element of the O2 sensor.

Incoming search terms:

2002-2005 Honda VFR800/A Wire Harness Replacement Manual

0

Filed Under (Honda) by admin on 21-04-2011

download
If the 18P (light blue) connector is in abnormal condition as shown below, contact TechLine at (800) 421-1900, option 9. FRONT SUB-HARNESS REPLACEMENT 1. Remove the front sub-harness from the cowl stay hooks. Disconnect all the electrical components from the front sub-harness. 2. Temporarily set the main wire harness aside, and disconnect the 6P (natural) con- nector. Then, carefully remove the front sub-harness. 3. Install the new front sub-harness by con- necting the 14P (natural) and 18P (light blue) connectors. NOTE: For routing specifications, refer to the WIRING & HARNESS ROUTING SECTION on pages 7-8. 4. Attach the front sub-harness on the cowl stay hooks. Make sure the front sub-harness is routed elow the main sub-harness. ABNORMAL CONDITION STAY HOOKS 6P (NATURAL) CONNECTOR FRONT UB-HARNESS 14P (NATURAL) CONNECTOR 18P (LIGHT BLUE) CONNECTOR FRONT SUB-HARNESSSTAY HOOK Page 4 VFR800/A #4 4 of 12 NOVEMBER 2007 5. Place the front sub-harness between the radiator and the frame, and below the rec- tifier. Be careful not to damage the front sub-harness or other components. 6. Re-connect the front sub-harness to the 6P (natural) connector. 7. Secure the main wire harness and the front sub-harness using the longer wire band. 8. Secure the main wire harness and the upper side of the front sub-harness using the shorter wire band. Adjust the wire har- ness located within the frame and the radi- ator hose accordingly. 9. Secure the main wire harness fuse box to the front sub-harness using the shorter wire band. FRONT SUB-HARNESS STAY HOOK MAIN-HARNESS FRONT SUB-HARNESS FRONT SUB-HARNESS 6P CONNECTOR (Male) 6P CONNECTOR (Female) WIRE BAND (LONG) WIRE BAND (SHORT)
WIRE BAND (LONG) WIRE BAND (SHORT) MAIN WIRE HARNESS FUSE BO

Incoming search terms:

2001 Honda GL1800 Oxygen Sensor Replacement Manual

0

Filed Under (Honda) by admin on 05-04-2011

download
REPAIR PROCEDURE 1. Remove the top shelter (see page 2-10 in the Service Manual). 2. Remove the left and right O 2 sensors from the exhaust pipes. • You do not have to remove the exhaust pipes to remove the O 2 sensors. • Be sure to note the wire routing for proper reassembly. 3. Install the new O 2 sensors and route the wires properly (see pages 1-33 and 1-34 in the 2001- Service Manual). 4. Connect the black 4P female coupler of the sub- harness kit to the wire harness side black 4P male coupler (for the left-side O 2 sensor). 5. Connect the new left O 2 sensor to the black 4P coupler on the sub-harness. 6. Route the sub-harness from left to right, across the front edge of the fuel tank and secure it with the clip on the cruise actuator 7. Cut off the right 4P male O 2 sensor coupler (on the wire harness side). 8. Install a PVC cap onto the end of the Black/yellow wire and Green/red wire (these are the wires that were connected to the coupler that was removed in step 7). Fold each cap back and tape it securely to its wire; these wires are no longer used. • Do not cut the wires off, just tape them back. • The tape is supplied in the replacement kit. 9. Strip the ends of the White and Black/red wires (which were connected to the coupler that was removed in step 7) on the wire harness side and the 2P coupler on the sub-harness. Install a heat shrink tube on each wire of the sub harness. 10. Twist the ends of the White and Black/red wires of the sub-harness 2P coupler to the White and Black/red wires of the main harness. 11. Solder the wires using the solder from the kit. 12. Use a heat gun to secure the heat-shrink tubing over the soldered wires. 13. Connect the right O 2 sensor coupler to the white 4P male coupler on the sub harness.

HI-4 DUAL FIRE MOTORCYCLE IGNITION INSTALLATION INSTRUCTIONS

0

Filed Under (Yamaha) by admin on 09-11-2010

download
Turn ignition switch off and disconnect battery ground cable. 2. Refer to Figure 3. Remove OE ignition module and wire harness (items 1-4). You will disconnect two wires at the coil (15), a wire going to the VOES (Vacuum Operated Electrical Switch) (18), a black ground wire at the ignition module, and the 3 pin plug (20) that connects to the sensor plate (11). Refer to shop manual for locations. 3. Remove ignition cover plates and gasket (items 5- 9). This will require drilling out two rivets. The rivets will later be replaced with two supplied self- threading screws. 4. In order to remove the sensor plate cable, the cable plug (20) must be removed first. Use needle nose pliers to pull the terminals out of the plug. Then pull the cable through the exit hole at the bottom of the timing cover. 5. Note location of sensor plate (11). There is a V notch in the sensor plate used for alignment. When you install the HI-4, you should align the V notch in the same location. This should set the timing close enough to start the engine. Remove and save the two standoffs and washers (10). Remove the sensor plate (11). HI-4 INSTALLATION Refer to Figure 4. The HI-4 requires use of the OE timing rotor P/N 32402-83 (used only on 1985 and newer models). If you have an older model or are not sure, check the rotor (9) for the correct part number. For models prior to 1980, use the supplied 10-32 x ¾”bolt and washer to mount the rotor. 1. Install the HI-4 system in place of the OE breaker or sensor plate. Rotate the HI-4 about 90 degrees to give better access to the cable exit hole. Install the HI-4 first, then push the cable through the hole. On some early models it may be necessary to enlarge the wire harness exit hole in the gear cover. Align the V notch on the HI-4 same as the OE plate you removed. Use the OE standoffs to secure the HI-4. You must use lockwashers under the standoffs for proper clearance between the HI-4 and cover plate. Do not fully tighten the standoffs until the timing has been set. 2. Route the HI-4 wire harness along the frame rails up to the coil. Make sure that harness will not be chafed or burned by exhaust heat. Secure harness with tie wraps. Do not install timing cover. HI-4 HOOKUP Crimp terminals and hardware are supplied for your convenience. Use the ring terminals for coil hookup. Use male-female quick disconnects for connections to the tach and vacuum switch (VOES). Tape up any unused wires. 1. Circuit Breaker Cover Screws (2) 2. Circuit Breaker Cover 3. Circuit Breaker Cover Gasket 4. Breaker Plate Screws (2) 5. Breaker Plate Screw Lockwashers & Washers (2 each) 6. Retainer (1971 to early 1972) 7. Circuit Breaker Cam Bolt 8. Breaker Plate Assembly 9. Breaker Cam 10. Advance Assembly 11. Gear Case Cover 11 10 9 8 7 6 5 4 3 2 1 NOTE: Damage will result if the brown tach wire comes in contact with +12V. Figure 1. Harley-Davidson®OE Points System
9000-4002A REV A 3 2/05 1. Identify switched +12 volt wire and tach wire (if equipped) going to the coil. Refer to your service manual, or reconnect the battery and use a test light or voltmeter. The switched +12 volt wire will be hot when the ignition key is turned on. 2. Refer to Figure 5. Connect the HI-4 red wire and switched +12 volt wire to Coil positive. 3. The HI-4 white wire is not used and should be taped. 4. Connect the HI-4 black wire to the Coil negative terminal. 5. Connect the HI-4 green wire to the vacuum switch (Figure 3, item 18), if used. 6. Connect the HI-4 brown wire to the tach wire, if equipped with tach. Tape up if unused. 7. The HI-4 is grounded via the timing housing; a separate ground connection is not required. 8. Reconnect battery ground cable. Verify proper ground connections to the frame and engine. VOES HOOKUP The OE vacuum switch (VOES) is normally an open circuit. Above 3-5 inch-Hg vacuum, the VOES closes and grounds the vacuum input on the OE ignition module. This increases the total advance generated by the OE ignition module. Vacuum advance improves part throttle 17 16 1. Cover Screws (2) 2. Ignition Timer Cover 3. Ignition Module 4. Timer Plate Screws (2) 5. Washers (2) 6. Screws & Washers (2 each) 7. Shield 8. Sensor 9. Trigger Rotor Bolt 10. Timer Plate 11. Trigger Rotor 12. Advance Assembly 13. Gear Case Cover 14. Ignition Coil 15. Spark Plug Wires (2) 16. Ignition Coil Terminal (FX) 17. Ignition Coil Terminal (FL) 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NOTE: Most motorcycle coils do not have terminals marked. Use either terminal for Coil+ (positive) and the other one for Coil- (negative). Warning: The HI-4 (8-1100) Dual Fire ignition will not work with 2 plugs per head, dual coil application. Damage will result if attempted. Use the HI-4 (8-2100) single fire ignition for 2 plugs per head applications

Incoming search terms:

SR-C400 Motorcycle Security System INSTALLATION MANUAL AND USER'S GUIDE

0

Filed Under (Tips and Review) by admin on 29-01-2011

download
Routing the Antenna Wire The MCM includes an 18″ antenna wire. The first 12″ is a coaxial wire; the remaining 6″ is the reception antenna wire. When routing, try to avoid running the antenna along or near metal. For best performance, have the antenna wire as vertical as possible and exposed. Wire Connections The system includes one harness (HAR-1a) that connects directly into the MCM. The harness is split into three plugs: one for the GEN-1a connector, one for the optional SN-5 connector and one for the data output for future expansion. Note: Each plug is unique and will only fit the appropriate component one way. Main Harness Note: If the optional factory connector kit is being used, please disregard this section of the instructions and refer to the instructions supplied with the factory connector kit. The main harness consists of two harnesses. One is labeled (HAR-1a) and the second is labeled (GEN-1a). Plug in the white 4 pin connector from the (HAR-1a) into the matching 4 pin connector from the (GEN-1a). The (HAR-1a) also has a waterproof connector that plugs into the MCM. The wires should be connected as follows: HAR-1a Black wire with fuse and ring terminal – To battery Positive (+). GEN-1a Black wire – To ground (-). Orange wire – To tail light wire or any other wire that is hot (+) when ignition is ON (NOTE: this is an input to the alarm this connection is not designed to flash the tail light). Color Codes: Ground (-) Tail Light Honda Green wire Brown wire Kawasaki Black wire Red wire Suzuki Black/White Brown wire Yamaha Black wire Blue wire Harley Davidson Black wire Blue wire

Incoming search terms:

2004 or later Harley Davidson Speedometer Installation MANUAL

0

Filed Under (Harley Davidson) by admin on 25-03-2012

download
Speed Sensor Installation: The microSpeed™ speedometer can be used with either +12V or +5V hall effect electronic sensors located in transmission. Sensor is not include. If your sensor operates on +5V DC wire speedometer to sensor and power as shown in Figure 2 below. Please note that color of wires from the sensor may vary, check sensor documentation for proper signal connections. For +12V sensor you will not need the Blue wire of the microSpeed™ speedometer. It may be cut short, but make sure that the end is properly protected so that it will not accidentally short to metal on the motorcycle. Use Figure 3 below for wiring a +12V sensor. H-D motorcycles 1999 and earlier used +12V sensors. H-D motorcycles 2000 and later use +5V sensors. Note: H-D OEM sensors require 20Kohm resistor(provided) between Sensor power and Sensor signal as shown. Procedure: 1. Locate wires and determine connection points. Cut wires and techflex to proper lengths. 2. Connect speedometer wires to proper signal wires as shown in diagrams, including 20K ohm resistor if using stock H-D sensor. Use either butt connectors provided or customer supplied connectors. 3. Use electrical tape or Heat Shrink tubing around sensor signal wire, sensor power, and resistor to protect resistor. 4. Proceed to Setup Section below. Setup microSpeed™ Speedometer: 1. Before proceeding review User Guide document for detailed instructions on following procedure. 2. Turn on power to speedometer, display should read “odo” 3. Set initial odometer value 4. Turn off power for 2 seconds; then turn power on again 5. Display should read “F 0″ 6. Enter Configuration and Calibration and set speedometer to proper operating mode. a. Harley English b. Harley Metric c. Standard speed sensor English d. Standard speed sensor Metric 7. Set Fuel miles per tank 8. Set Oil change interval 9. Set Speed adjustment 10. Confirm. 11. Test speed is reporting properly and adjust is necessary

Incoming search terms: