air cut off valve 1983 honda vt750c hard starting

You search Auto repair manual PDF air cut off valve 1983 honda vt750c hard starting, if there are search results will appear below. If search results do not exist, please search by others keyword.



  air cut off valve 1983 honda vt750c hard starting Direct Download speed 5282 Kb/s

  air cut off valve 1983 honda vt750c hard starting Full Version speed 6162 Kb/s



2001 YAMAHA TDM900 SERVICE MANUAL

0

Filed Under (Yamaha) by admin on 20-11-2010

download
CHECKING THE SWITCHES ELEC EAS00731 ELECTRICAL CHECKING THE SWITCHES Check each switch for damage or wear, proper connections, and also for continuity between the terminals. Refer to “CHECKING SWITCH CONTINUITY”. Damage/wear Repair or replace. Improperly connected Properly connect. Incorrect continuity reading Replace the switch. -3- ELECTRIC STARTING SYSTEM ELEC EAS00755 ELECTRIC STARTING SYSTEM CIRCUIT DIAGRAM -4- ELECTRIC STARTING SYSTEM ELEC 4 Main fuse 5 Battery 7 Starter relay 8 Starter motor 9 Main switch 12 Starting circuit cut-off relay 13 Sidestand switch 14 Neutral switch 49 Clutch switch 59 Engine stop switch 60 Start switch 61 Ignition fuse -5- ELECTRIC STARTING SYSTEM ELEC EAS00756 STARTING CIRCUIT CUT-OFF SYSTEM OPERATION If the engine stop switch is set to “” and the main switch is set to “ON” (both switches are closed), the starter motor can only operate if at least one of the following conditions is met: The transmission is in neutral (the neutral switch is closed). The clutch lever is pulled to the handlebar (the clutch switch is closed) and the side- stand is up (the sidestand switch is closed). The starting circuit cut-off relay prevents the starter motor from operating when neither of these conditions has been met. In this instance, the starting circuit cut-off relay is open so current cannot reach the starter motor. When at least one of the above conditions has been met the starting circuit cut-off relay is closed and the engine can be started by pressing the starter switch. WHEN THE TRANSMISSION IS IN NEUTRAL WHEN THE SIDESTAND IS UP AND THE CLUTCH LEVER IS PULLED TO THE HANDLEBAR 4. Starting circuit cut-off relay Disconnect the starting circuit cut-off relay from the wire harness. Connect the pocket tester (Ω 1) and battery (12 V) to the starting circuit cut-off relay terminals as shown. YES NO Replace the starting circuit cut-off relay. Does the starting circuit cut-off relay have continuity between blue/white and black? EAS00759 Continuity Tester positive probe sky blue Tester negative probe blue/yellow No conti- nuity 1 2 1 3 Tester positive probe sky blue Tester negative probe black/yellow Battery positive terminal red/black Battery negative terminal black/yellow 1 2 Tester positive prove blue/white Tester negative prove black 3 4 5. Starting circuit cut-off relay (diode) Disconnect the starting circuit cut-off relay from the wire harness. Connect the pocket tester (Ω 1) to the starting circuit cut-off relay terminals as shown. Measure the starting circuit cut-off relay for continuity as follows. Tester positive probe blue/green Tester negative probe blue/yellow 4 3 Tester positive probe black/yellow Tester negative probe sky blue 2 1 Tester positive probe blue/yellow Tester negative probe sky blue 3 1 Tester positive probe blue/yellow Tester negative probe blue/green 3 4 When you switch the tester’s positive and negative probes, the readings in the above chart will be reversed. Are the testing readings correct? YES NO Replace the starting circuit cut-off relay. NOTE: EAS00760

Incoming search terms:

TVS – 811 Series Trap Valve Station Installation, Operation and Maintenance Instructions

0

Filed Under (TVS) by admin on 29-04-2012

download
In a piston valve, the control of stem and seat leakage is obtained by tightness of the valve sealing rings to the body and valve plug. The bonnet compresses the valve sealing rings against the body and the valve plug. Flexible disc springs automatically assure a tight seal by exerting pressure on the valve sealing rings, keeping them compressed. Opening and Closing the TVS Isolation Valves The isolation valve begins to stop flow when the valve plug enters the lower valve sealing ring. When the isolation valve is completely closed, the valve plug is in contact with the full height of the valve sealing rings, ensuring the best possible seal. In fact, there is no advantage to be gained in torqueing the valve closed. Armstrong recommends that after closing the isolation valves completely, the handwheel should be turned back one half turn. This makes it easy to re-open the valve by avoiding metal to metal seizure. Troubleshooting – Isolation Valves A piston valve will retain its leak tightness for several years without maintenance. In severe service, such as rapid heating and cooling, some field maintenance may be required. Depending on the problem, these simple steps may help: ! ! ! ! ! Isolation Valve leaks, when the valve is closed . First, Check to make sure the valve is actually closed . Check to see if bonnet is seated on the body, if not, tighten the bonnet nuts until the bonnet seats. This recompresses the valve sealing rings against the body and the valve plug. If valve continues to leak, replace the isolation valve assembly

Incoming search terms:

2005 Honda CRF450X OWNER'S MANUAL AND COMPETITION HANDBOOK

0

Filed Under (Honda) by admin on 04-12-2010

download
Starting & Stopping the Engine Always follow the proper starting procedure described below. Your CRF can be started with the transmission in gear by pulling in the clutch lever before operating the kickstarter or start button. Preparation Make sure that the transmission is in neutral. Turn the fuel valve ON. Fuel Valve Starting Procedure Always follow the proper starting procedure described as follow. 5. Warm up the engine; don’t operate the throttle. 6. About 15 seconds after the engine starts, push the choke knob back all the way to fully OFF. If idling is unstable, open the throttle slightly. Extended use of the choke may impair piston and cylinder wall lubrication and damage the engine. HighAirTemperature 35°C (95°F) or above 1. Turn the fuel valve (1) ON. 2. Do not use the choke. 3. Keep the throttle fully closed. 4. Start the engine following step 4 under “Normal Air Temperature.” LowAirTemperature 10°C (50°) or below 1. If the temperature is below 32°F (0°C), open the throttle two or three times. (The engine requires a richer mixture for starting in cold weather. When the throttle is so opened, the accelerator pump will feed extra fuel to the cylinder, thereby facilitating starting in cold weather.) 2. Follow steps 1-5 under “Normal Air Temperature.” 3. Continue warming up the engine until it runs smoothly and responds to the throttle when the choke knob is pushed back all the way to fully OFF. Extended use of the choke may impair piston and cylinder wall lubrication and damage the engine. (cont’d) NOTICE NOTICE Basic Operating Instructions 15 (1) fuel valve The three-way fuel valve is used to control the flow of fuel from the fuel tank to the carburetor. ON -Turning the fuel valve ON before attempting to start the engine allows fuel to flow from the fuel tank to the carburetor. OFF -Turning the fuel valve OFF prevents the flow of fuel from the fuel tank to the carburetor. RES -Turning the fuel valve to RES allows fuel to flow from the reserve fuel supply to the carburetor. (1) fuel valve (2) choke knob Check the engine oil, transmission oil and coolant levels before starting the engine (pages 44,47,48). To restart a warm engine, follow the procedure for”High Air Temperature.” NormalAirTemperature 10°C-35°C (50°F-95°F) 1. Turn the fuel valve (1) ON. 2. Pull the choke knob (2) fully ON, if the engine is cold. 3. Keep the throttle fully closed. 4. Pull the clutch lever all the way in, and depress the start button. Or operate the kickstarter to start the engine. Starting from the top of the stroke, kick through to the bottom with a rapid, continuous motion. Do not operate the throttle. Allowing the kickstarter to snap back freely against the pedal stop can damage the engine

Incoming search terms:

HONDA CRF250X OWNER'S MANUAL

0

Filed Under (Honda) by admin on 01-12-2010

download
Always follow the proper starting procedure described below. Your motorcycle can be kickstarted wirh the transmission in gear by pulling in the clutch lever before operating the kickstarter. Preparation Make sure that the transmission is in neutral. Turn the fuel valve ON. Fuel Valve Starting Procedure Always follow the proper starting procedure described as follow. 4. Warm up the engine; don’t operate the throttle. 5. About 15 seconds after the engine startes, push the choke knob back all the way to fully OFF. If idling is unstable, open the throttle slightly. Extended use of the choke may impair piston and cylinder wall lubrication and damage the engine. High Air Temperature 35°C (95°F) or above 1. Do not use the choke. 2. Keep the throttle fully closed. 3. Start the engine following step 3 under Normal Air Temperature. Low Air Temperature 10°C (50°) or below 1. Follow steps 1-4 under Normal Air Temperature. 2. Continue warming up the engine until it runs smoothly and responds to the throttle when the choke knob is pushed back all the way to fully OFF. Extended use of the choke may impair piston and cylinder wall lubrication and damage the engine. Hot Engine Starting 1. Pull the hot start lever (3) and start the engine following step 3 under Normal Air Temperature. 2. As soon as the engine starts, release the hot start lever. NOTICE NOTICE Basic Operating Instructions 15 (1) fuel valve The three-way fuel valve is used to control the flow of fuel from the fuel tank to the carburetor. ON -Turning the fuel valve ON before attempting to start the engine allows fuel to flow from the fuel tank to the carburetor. OFF -Turning the fuel valve OFF after stopping the engine prevents the flow of fuel from the fuel tank to the carburetor. RES -Turning the fuel valve to RES allows fuel to flow from the reserve fuel supply to the carburetor. (1) fuel valve (2) choke knob Check the engine oil, transmission oil and coolant levels before starting the engine (pages 44,47,48). To restart a warm engine, follow the procedure for ”High Air Temperature. ” Normal Air Temperature 10°C-35°C (50°F-95°F) 1. Pull the choke knob (2) up all the way to fully ON, if the engine is cold. 2. Keep the throttle fully closed. 3. Pull the clutch lever all the way in, and press the starter button with the throttle completely closed. Or operate the kickstarter to start the engine. Starting from the top of the stroke, kick through to the bottom with a rapid, continuous motion. Do not operate the throttle. Allowing the kickstarter to snap back freely against the pedal stop can damage the engine case.

Air Shock Installation Instructions

0

Filed Under (Tips and Review) by admin on 24-11-2010

download
Air HoseInstallation. Choose the most convenient loca- tiononyour motorcycle for the air fill valve. Drilla 5/16″hole and install the air fill valve as shown in Figure 3orsecure air fill valve to frame tube. 2. Keep hose ends clean during installation because dirt can cause air leaks. 3. Install hose connector, tube clamp and two O-rings onto one end of the air hose (See Figures4&5) Apply rubber lubricant (soap solution, not oil) to the O-rings to ease installation on the air hose& into the shock absorber inlet. Plastic connector should just bottom on fitting. Do not overtighten! The function of the nut is to hold everything together in place, the O- rings do the sealing. Fin- gertightenonly (10 in/lb maximum). 4. After routing the air hose, trim the length to fit air fill valve. Install hose connector, tube clamp, and twoO-rings onto end of hose (See figures 4&5). Lubricate as above and assemble to air fill valve. Use the same procedure formating hose. Important —leaveasmall amount of slack in hose near shock absorber to allow for the slight move- mentofthe shock. Caution! Do not install hose near ex- haustsystem, battery or any other sharp edges or seat movement. Keep hoses clear of moving parts such as wheels or suspension components. Do not allow hoses to have excess slack and sag below the motorcycle. The hoses could catch on road surfaces or debris and could be damaged while the motorcycle is in motion. 5. If necessary the air hose can be secured along the motorcycle’swiringharness with tie-wraps. 6. Testing: Inflate system to 50 psi. Apply soapy water solution to all connections and check for air leaks. If there are any leaks, disconnect the suspected fitting and check for dirt or damage to the air line or the O-rings. Remove any dirt or foreign matter, re-lubricate the O-rings and reinstall. If unable to locate the leak, remove rubber boot from shocks and submerge pressurized components under water (in- cludingT-Valve) and check for leaks. If you cannot solve the air leak problem, please contact our technical staff for assistance

Victory Freedom Engines Installation Instructions for S&S Air Cleaner Kit

0

Filed Under (Victory) by admin on 31-10-2010

download
1-Locate and remove the Intake Air Temperature Sensor (IATS) from the stock Polaris Victory air box. Locate the new position for the IATS on the bottom of the S&S air cleaner. Push the IATS in the lower air cleaner cover and turn1⁄ 4 turnin either direction, make sure you feel it lock into place. Inspect from the inside of the air cleaner to ensure that the barbs are locked into place. See Picture 1. 2-Using the stock Polaris Victory air box gasket (PN 5811908) and S&S supplied (Qty 4) M6 fasteners, assemble the lower air cleaner cover to the throttle body using 243 Blue Loctite®on the treads. Torque the M6 fasteners to 72-96 inch pounds. 3-Position the S&S pre-formed air filter onto the lower air cleaner cover ensuring that it fits into the machined groove. 4-Install the top air cleaner cover on top of the filter ensuring that it fits into the machined groove. 5-Make surethat the filter is situated in the machined grooves on both the top and bottom air cleaner covers. 6-Using 243 Blue Loctite on the threads of the S&S supplied (Qty 3) M6 fasteners tighten down top air cleaner cover evenly until seated. Finish torque the fasteners to 72-96 inch pounds. Now you’re ready for breather hose and barometric pressure hose routing. 7-Locate the S&S supplied 3⁄ 16 “reinforced hose and clamps. Push one end of the hose on the 3⁄ 16 “brass barb in the bottom air cleaner cover and slide clamp up around the end of the hose. The other end of the hose is for the Barometric Pressure Sensor (MAP). Route the hose towardthe back of the engine over the top of the rear rocker cover. 8-Remove the MAP sensor from the stock Polaris Victory air box. Remove the orange rubber gasket from the MAP sensor. Slide the S&S supplied clamp over the 3⁄ 16 “rubber hose that leads to the air cleaner. Push the barbed end of the MAP sensor into the 3⁄ 16 ” rubber hose and slide clamp up to the end of the hose around the barb. A small amount of lubricant may be applied to the barb on the MAP sensor to make installation easier. 2 S&S Air Cleaner Assembly 41-0021 (Calibration cardnot shown) Picture 1 CAUTION WARNING WARNING Plastic barb locked in recess.
9-Assemble and install breather hose as follows: A-Cut the stock Victory®hose on the straight section just behind the 90 degree bend as shown in Picture 2 . B-Slide an S&S supplied 1⁄ 2 “hose clamp over the modified stock breather hose. C-Install the S&S straight barb in Victory breather hose and position a hose clamp around hose end. D-Slide the 90-degree end of breather hose over the brass barb on the air cleaner cover and slide hose clamp in place. E-Position straight end of the S&S breather hose over the 1⁄ 2 “barb to connect to the Victory hose. Slide clamp over connection. F- See Pictures 3 and 4 for breather hose and barometric pressuresensor hose installation positions. NOTE: S&S breather hose can be cut for best fit

Incoming search terms:

HONDA CBX 750F (RC17) OWNERS MANUAL

0

Filed Under (Honda) by admin on 26-11-2010

download
Front air pressure adjustment: 1. Place the motorcycle on its centre stand. Do not use the side stand, or you will get false pressure readings. 2. Remove the front fork air valve cap (1). Check the air pressure. NOTE: Some pressure will be lost when removing the gauge from the valve. Determine the amount of loss and compensate accordingly. 3. Add air to the recommended pressure. NOTE: We recommend that you do not exceed the recommended air pressure or the ride will be harsh and uncomfortable. 4. Reinstall the front fork air valve cap. Rear air pressure adjustment: 1. Place the motorcycle on its centre stand. 2. Do not use the side stand, or you will get false pressure readings. 3. Remove the right side cover. 4. Remove the valve air cap (2). Check the air pressure with an air pressure gauge. NOTE: Some pressure will be lost when removing the gauge from the valve. Determine the amount of loss and compensate accordingly. 5. If required, add air up to the recommended pressure. 6. Reinstall the air valve cap (2) and the right side cover

Incoming search terms:

MOUNTAIN BIKE AIR SHOCK SET-UP AND TUNING GUIDE

0

Filed Under (Tips and Review) by admin on 01-12-2010

download
DETAILED SET-UP 2. Installing Air Pressure – Remove the air cap from the Schrader valve on the end of the shock body. Attach the pump to the Schrader valve. Some people damage their pumps by screwing them on too far. As soon as the gauge registers pressure, screw 1/2 turn more and pump to the desired level. Use the release button on the pump to reduce air pressure. The hiss you hear when unscrewing the pump is only the air from the pump and not from the shock! Likewise, when you install the pump again, you will also hear a hiss as air from the shock fills the pump and reduces the registered pressure you previously installed. All perfectly normal when pressurizing the shock! After removing the pump, be sure to reinstall the Schrader valve cap. If the shock does not dampen properly after pressurizing, the air pressure may have been lost during pump removal as a result of a worn pump fitting o-ring that needs replacement. Do not ride the bike until the shock is properly pressurized. 3. Main Air Spring Pressure Adjustments – Air Spring adjustments are made by inflating or deflating the main air spring chamber. Since your IFP air pressure adjustment (outlined above) also affects your starting spring force, you should always adjust your IFP pressure before adjusting the main air spring pressure. You can refer to the online Quick Start guide at: www.progressivesuspension.com/literature.html for accurate main air spring pressure and sag settings matched to your bike model and body

Incoming search terms:

2009 Kawasaki ULTRA 250X/ 260X FUEL INJECTION CONTROLLERS And REGULATORS INSTALLATION MANUAL

0

Filed Under (Kawasaki) by admin on 25-10-2010

download
The R&D high performance Air Filter Kit will improve acceleration and top speed performance by increasing air flow and reducing air temperatures that enter directly into the Ultra 250X’s air plenum box area. The O.E.M. air plenum box on the Ultra 250X is a great design that will flow plenty of air. However, the air that feeds the plenum box is heated by the engine. R&D has created an easy to install “flat filter” that installs directly in place of the large center access inspection cover located directly under the main glove box. The R&D Flat Air Filter insert will allow unrestricted fresh and cool air to enter the air plenum box area which will add power you can feel and a nice high performance tone. The R&D Performance Filter Kit also features two filters, one for each of the surge and blowoff protections valves. The O.E.M. surge valve recycles compressed hot air back into the air box plenum at idle and under deceleration conditions. The R&D surge and blowoff valve filter kit removes the air recycling hoses which will keep the hot air from entering the air plenum box reducing the engines intake air temperatures. The R&D Ultra 250X Air Filter Kit offers great performance tips on how to remove the restrictive air vent hoses which will further reduce the under seat ambient air temperatures. The R&D Filter system does not remove or alter the O.E.M. plenum box in any way, therefore there are no questions to be answered regarding water ingestion

Incoming search terms:

CYLINDER HEAD REPAIR MANUAL

0

Filed Under (Tips and Review) by admin on 28-10-2010

download
ADJUSTABLE CYLINDER HEAD STAND Head can be rotated 360 degrees. Stays in any position using a simple locking mechanism. Use on twin or four cylinder heads. Shipping weight: 14 lbs. Adjustable length-10-1/2″ to 20-1/2″ long x 14″ width x 10-3/4″ high. 35-8602 Cylinder Head Stand VALVE GUIDE DRIVERS Use for removal and installation of valve guides into cylinder head. Available in the following sizes: 35-8418 4.5mm YM-4116 35-8416 6mm YM-4064-A 35-8417 5mm YM-4097 35-8414 7mm YM-1225-A 35-8408 5.5mm YM-1122 35-8413 8mm YM-1200 VALVE GUIDE DRIVER SET (REMOVE & REPLACE) Designed for speed and accuracy, this eleven piece set provides the right tool for the job. Driver set includes two valve guide drivers (5.5mm and 6.6mm), four valve guide installers, one cutter, three cutter pilots (5.5mm, 6.6mm, and 7.7mm) and one tap handle extension bar. 35-9445 Valve Guide Driver Set YAMAHA VALVE GUIDE INSTALLERS These installers are used for installation of Yamaha shoulder less valve guides to a specific depth into the cylinder head. To use, position onto the valve guide and drive into the cylinder head until installer makes contact with cylinder head surface. Note: Must use with Valve Guide Driver. Available in the following sizes: 35-8439 4.5mm YM-4117 35-8437 5.0mm YM-4098 35-8419 5.5mm YM-4015 35-8435 6mm YM-4065-A 35-8423 7mm YM-4017 VALVE GUIDE REAMERS Reaming valve guides after installation assures a proper valve stem to valve guide fit. Available in the following sizes: 35-3829 4.5mm YM-4118 35-3851 7mm YM-1227 35-3836 5.5mm YM-1196 35-3852 8mm YM-1211 35-3847 6mm YM-4066 CLOVER VALVE LAPPING COMPOUND KIT The world famous green can with the four leaf clover. For seating valves, mating gears, and sharpening. Sold as a kit with coarse 120 grit (roughing) and 280 fine grit (finishing). 35-0309 Clover Valve Lapping Compound VALVE LAPPING TOOL The ultimate vacuum stick for insuring perfect surfaces on valves and valve seats. Interchangeable cups make unit suitable for use with virtually any size valve. Set includes vacuum stick, 3/4″ and 1/4″ diameter rubber cups. 35-8998 Valve Lapping Too

Incoming search terms:

Incoming search terms: