HARLEY-DAVIDSON SOFTAIL CROSSOVER REMOVAL AND INSTALLATION INSTRUCTIONS

0

Filed Under (Harley Davidson) by admin on 01-04-2012

download
EXHAUST SYSTEM REMOVAL READ ALL INSTRUCTIONS BEFORE BEGINNING 1. Under the oil tank on the right hand side, locate the rear O² sensor connector. Unplug sensor and feed the end of wire through the frame freeing it from motorcycle. NOTE: Pay attention to wire routing for re-installation. 2. Open the plastic cover above the rectifier on front of the frame to access to the front O² sensor connector. Unplug sensor from harness. Remove ZIPSTRIP holding wire to frame and feed the wire through freeing it from motorcycle. 3. On floorboard equipped models, loosen the right hand floorboard mounting bolts to gain clearance for exhaust removal and installation. 4. Loosen the heat shield clamps on both front and rear exhaust pipes. 5. Remove the mounting nuts from each head pipe, located at the cylinder head. 6. Remove the nuts attaching the exhaust mount bracket to the frame. 7. On FLSTD and FLSTF models, you will need to remove the right side passenger foot peg and hanger, as this is attached to the exhaust mount bracket. Replace the passenger foot peg assembly using the BOLT 14 Allen bolt (supplied). 8. Remove the entire exhaust system and set it aside. 9. Remove the two lower mounting studs from the frame See figure 1 . Recommended replacement exhaust port gaskets, H-D P/N: 65324-83A. 10. Carefully remove exhaust port flanges and circlips from the stock exhaust system using snapring pliers. See figure 2 . NOTE: Replace bent or damaged circlips. Check exhaust port gasket condition. 11. Remove O² sensors from stock head pipe and set aside for re-installation on your new RUSH exhaust system. PAGE 1 OF 4 RUSH RACING PRODUCTS EXHAUST SYSTEM INSTALLATION P/N 7020 – 7120 BEFORE INSTALLATION PLEASE READ ALL INSTRUCTIONS 1. Remove header and heat shields from protective packaging. Place each heat shield on a non-abrasive surface such as a blanket or carpet. Using a felt tip pen, mark outside edge of each heat shield to show location of mounting clips that hose clamps will loop through See figure 3. 2. Apply a small amount of anti-seize compound to the threads of the O² sensors and install them into the new head pipe. NOTE: Be careful not to get anti-seize on sensor tip, it may affect sensor function. 3. Install circlips and flanges from stock system onto the new head pipe See Figure 2. Note: Replace circlips if bent or damaged 4. Attach BRKT-007 to frame using two BOLT 12 Tighten to factory specs. 5. Install complete assembly into exhaust ports (rear port first). Use stock flange nuts, Do Not Tighten .

Incoming search terms:

HARLEY-DAVIDSON SOFTAIL STRAIGHTSHOTS 2-2 INSTALLATION MANUAL

0

Filed Under (Harley Davidson) by admin on 21-03-2012

download
1. Under the oil tank on the right hand side, locate the rear O2 sensor connector. Unplug sensor and feed the end of wire through the frame freeing it from motorcycle. NOTE: Pay attention to wire routing for re-installation. 2. Open the plastic cover above the rectifi er on front of the frame to gain access to the front O2 sensor connector. Unplug sensor from harness. Remove cable tie holding wire to frame and feed the end of the wire through, freeing it from motorcycle. 3. On FLSTC, FLSTF, FLSTN and FLSTSC models, loosen the right hand fl oor board mounting bolts to gain clearance for exhaust removal and installation. 4. Loosen the heat shield clamps on both front and rear exhaust pipes. 5. Remove the two mounting nuts from each head pipe, located at the cylinder head. 6. Remove the nuts attaching the exhaust mount bracket to the frame. 7. On FLSTN, FLSTF and FXSTD models, you will need to remove the right side passenger footpeg and hanger, as this is attached to the exhaust mount bracket. Remove hanger, and replace the passenger foot peg assembly using the 3/8″ x 2 1/2″ Allen bolt (supplied). 8. If equipped, unbolt the carriage bolt and clamp attached to the bracket under the right side transmission cover. 9. Remove the entire exhaust system and set it aside. 10. If equipped, remove the bracket from under the right side transmission cover. 11. Using a 7/8″ or 22mm wrench, carefully remove the O2 sensors from the stock head pipes and save for re-use with the new system. 12. Remove the two lower mounting studs from the frame (Figure 1). 13. Carefully remove exhaust port fl anges and circlips from the stock exhaust system using snapring pliers. NOTE: Replace bent or damaged circlips. Check exhaust port gasket condition. Recommended replacement exhaust port gaskets, Harley part number:17048-98 or 65324-83A

HARLEY-DAVIDSON SPORTSTER SHORTSHOTS STAGGERED BLACK INSTALLATION MANUAL

0

Filed Under (Harley Davidson) by admin on 17-03-2012

download
1. Find and unplug the O2 sensor wires from the wiring harness and remove nylon cable tie holding front wire to frame. Feed the end of the wires through the frame so they are free from the motorcycle. NOTE: Pay attention to wire routing for re-installation. 2. Loosen the heat shield clamps on both the front and rear exhaust pipes. This allows easier access to the head pipe mounting nuts. 3. Remove the two head pipe mounting nuts from each fl ange, located at the cylinder head. 4. Remove the clamp bolt which mounts the rear head pipe to the belt drive cover bracket. 5. Remove the two bolts from each muffl er body where they attach to the mounting bar. Carefully remove exhaust pipes from the motorcycle and set aside. 6. Using a 7/8″ or 22mm wrench, carefully remove the O2 sensors from the stock head pipes and save for re-use with the new system. 7. Remove the drive belt cover and take the bracket off the rear cover bolt, the bracket will not be re-used. 8. Loosen the brake rod at the rear eyelet using a T30 torx driver. 9. Remove the three mount bolts and washers attaching the exhaust mounting bar (save hardware for re-use). 10. Carefully remove exhaust port fl anges and circlips from the stock exhaust system using snapring pliers. NOTE: Replace bent or damaged circlips. Check exhaust port gasket condition. Recommended replacement exhaust port gaskets, Harley part number:17048-98 or 65324-83A.

HARLEY DAVIDSON DYNA SIDESHOTS BLACK INSTALLATION AND REMOVAL PROCEDURE

0

Filed Under (Harley Davidson) by admin on 25-02-2012

download
Remove seat to gain access to rear oxygen sensor connector. Unplug sensor and feed end of wire through frame so that it is free from motorcycle. NOTE: Pay attention to wire routing for re-installation. 2. Remove two bolts holding rectifi er onto front of frame (near front tire). Open plastic cover to gain access to front oxygen sensor connector. Unplug sensor from harness. Remove cable tie holding wire to frame and feed end of wire through so that it is free from motorcycle. 3. Loosen heat shield clamps on both the front and rear head pipes. 4. Remove two cylinder exhaust port fl ange nuts from each head pipe, located at the cylinder head. 5. Remove front head pipe clamp bolt. 6. Remove the bolt that attaches muffl ers to the frame mounting bar. 7. Remove the complete exhaust system and set aside. Assistance may be required. 8. Remove stock mounting bar and the studs in the transmisson cover. Save the bolts, one will be re-used. 9. Remove left bolt below the transmission cover. Position mounting bracket 405-P over mounting location to determine which bolts to remove (Figure 1). Install this bolt in the top hole left vacant by the new bracket. 10. Carefully remove the fl anges and circlips from the stock exhaust system using snapring pliers. NOTE: Replace bent or damaged circlips. Check condition of stock exhaust gaskets. Replace if worn or damaged. (Recommended replacement exhaust port gaskets, Screamin’ Eagle part number 17048-98)

HARLEY DAVIDSON Softail Big Shots Staggered Exhaust System Installation Manual

0

Filed Under (Harley Davidson) by admin on 20-12-2010

download
STOCK EXHAUST SYSTEM REMOVAL 1. If equipped, loosen the floor boards to gain clearance for exhaust removal and installation. 2. Loosen heat shield clamps on both the front and rear head pipes. 3. If equipped, loosen crossover pipe clamp, located between front and rear head pipes. 4. Remove two cylinder exhaust port flange nuts from each head pipe, located at the cylinder head. 5. Remove the bolts that attach mufflers to the frame. 6. Remove the complete exhaust system and set aside. Assistance may be required. 7. Remove stock mounting bars and brackets. 8. On models equipped with upper mounting bar attached at swing arm pivot bolt, go to step 9. If upper mounting bar is attached with two torx bolts (not swing arm bolt) go to step 10. 9. Remove right side 1/4″-20 bolt which holds lower fender in place. The fender will flex outwards allowing removal of right passenger foot peg bolt. Park the motorcycle on its side stand. Position a floor jack under right hand frame tube of the motorcycle below swing arm pivot bolt. Raise jack just enough to take the weight off swing arm pivot bolt. Remove swing arm pivot bolt and stock upper mounting bar. Replace swing arm pivot bolt and torque to 120 ft. lbs. Reinstall passenger foot peg using 1/2″-20 x 3″ bolt and 1 5/8″ long spacer (supplied). Reinstall 1/4″-20 fender bolt. 10. Using a T50 torx driver, remove the three mounting bolts and mounting bar. (Two of the bolts are visible, the third also attaches right hand passenger foot peg pivot and is accessed by removing foot peg. Reinstall foot peg using 3/8″x 2-1/2″ Allen bolt and 3/4″ long spacer (supplied). 11. Carefully remove exhaust port flanges and circlips from the stock exhaust system using snapring pliers. NOTE: Replace bent or damaged circlips. Check exhaust port gasket condition. (Recommended replacement exhaust port gaskets, Harley part number:17048-98 or 65324-83A)

VESPA GTS 250 i. e. EXHAUST MANIFOLD REPLACEMENT

0

Filed Under (Vespa) by admin on 11-11-2010

download
VE SPA GTS 250 i. e. EXHAUST MANIFOLD REPLACEMENT To replace the exhaust manifold, order part number 872659 as spare part following standard proceedings. OPERATION PROCEDURE The above picture references the old exhaust flange and the replacement exhaust flange kit part number 872659. Replacement Old Page 5 of 16 With the complete exhaust system removed from the vehicle remove the lambda sensors. Refer to page 88 and 89 of your Vespa GTS workshop manual for exhaust removal. Loosen the 13 mm bolt to loosen the clamp. Bolt Remove lambda sensor Page 6 of 16 Remove the header pipe from the exhaust box. Remove the exhaust packing and clamp. Remove exhaust manifold Gasket Clamp Page 7 of 16 Once all packing is removed check and make sure all surfaces are clean. This will help the installation of the exhaust gasket. Install the new clamp supplied with the kit, but do not tighten down at this point. Fit the exhaust gasket onto the new manifold. Push the new exhaust gasket in with the manifold until fitted all the way down to the flange. Check surfaces. Manifold Gasket Clamp Flange Page 8 of 16 Replace the lambda sensor and tighten down to 40- 50 Nm (29.5 -36.8 ft lbs. ) .